Search results for "Diameter ratio"

showing 4 items of 4 documents

Phenotypic traits of berries and seeds of Sicilian grape cultivars (Vitis vinifera L.)

2020

Abstract Grapevine is characterized by high variability in seed and berry morphology and their phenotypic traits are usually used to describe V. vinifera varieties. The goal of this study was to investigate the phenotypic diversity of berry and seed traits and the relationships between berry and seed morphological characteristics of autochthonous accessions of Sicilian germplasm. In two seasons, twenty bunches per cultivar were harvested at technological maturity. Berry weight; berry longitudinal and transversal diameters; seed number/weight per berry; and seed length, thickness, width and beak length were determined, after which the diameter ratio was calculated. Black and white cultivars …

0106 biological sciences0301 basic medicineGermplasmHigh variabilityfood and beveragesBerryPhenotypic traitHorticultureBiology01 natural scienceslanguage.human_languageSettore AGR/03 - Arboricoltura Generale E Coltivazioni Arboree03 medical and health sciencesHorticultureDiameter ratio030104 developmental biologylanguageBerry Seed Shape Size Beak Stummer’s and Perret’s indicesCultivarVitis viniferaSicilian010606 plant biology & botany
researchProduct

CT-Determined Maximum Pulmonary Artery to Ascending Aorta Diameter Ratio in Nonsevere COVID-19 Patients

2021

2019-20 coronavirus outbreakCoronavirus disease 2019 (COVID-19)business.industrySARS-CoV-2Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)COVID-19Pulmonary ArteryDiameter ratioText miningTomography x ray computedRadiology Nuclear Medicine and imagingmedicine.arteryPulmonary arteryAscending aortaMedicineHumansRadiology Nuclear Medicine and imagingbusinessNuclear medicineLetters to the EditorTomography X-Ray ComputedAortaAcademic Radiology
researchProduct

Effect of the height-to-diameter ratio on the mass transfer and mixing performance of a biotrickling filter

2017

BACKGROUND Biotrickling filters (BTFs) are among the most widely used biological technologies for air pollution control. The pollutant removal rate in BTFs relies to a large extent on its gas–liquid mass transfer performance. Therefore, knowledge of the design parameters affecting the mass transfer and mixing performance of full-scale BTFs is of paramount importance. RESULTS This work showed that the height-to-diameter (H/D) ratio is an important parameter in the design of BTFs devoted to air pollution control. The H/D ratio significantly affected the mass transfer and mixing performance of the BTF with and without additional stirring in the holding tank. It was observed that under the same…

Mass transfer coefficientWork (thermodynamics)Materials scienceRenewable Energy Sustainability and the EnvironmentGeneral Chemical EngineeringOrganic ChemistryMixing (process engineering)Environmental engineering02 engineering and technologyMechanics010501 environmental sciences021001 nanoscience & nanotechnology01 natural sciencesPollutionInorganic ChemistryDiameter ratioFilter (large eddy simulation)Fuel TechnologyLiquid velocityMass transferHolding tank0210 nano-technologyWaste Management and Disposal0105 earth and related environmental sciencesBiotechnologyJournal of Chemical Technology & Biotechnology
researchProduct

Influence of ocular aberrations on the diameter of retinal blood vessels

2011

Lower-order and higher-order ocular aberrations influence not only visual perception but also appearance of retinal images. We suggest that the diameter of blood vessels may differ for various patterns of aberrations based on how the maps of point spread functions are orientated to these vessels. We tested our hypothesis by a star chart simulation method and by using simulating aberrations in a real image of a living retina. We observed that broadening of the blood vessels due to ocular aberrations depends not only on the relative orientation of the wavefront but also on their actual width. The change in the diameter ratio is clinically significant and is comparable to changes in the arteri…

Retinal blood vesselsWavefrontRetinamedicine.medical_specialtygenetic structuresbusiness.industryRetinalFundus (eye)eye diseasesAtomic and Molecular Physics and OpticsPoint spreadDiameter ratiochemistry.chemical_compoundmedicine.anatomical_structureOpticschemistryOphthalmologyArteriovenous ratioMedicinesense organsbusinessJournal of Modern Optics
researchProduct